Generator The generator is a Onan MDKUB 6.5 KW unit installed in the aft lower section of the engine room pod. OperationTo start the generator: - 120V SELECTOR SWITCH in OFF position
- GEN CONTROL switch ON (located on side of navigation station seat)
- Press the PRE HEAT switch for 10-15 seconds
- NOTE: DO NOT HOLD START SWITCH ON TOO LONG THIS WILL BURN UP THE GENSET STARTER MOTOR
- Press the START switch until generator is running
- Assure cooling water flow from starboard stern area
- Let generator warm up for 3 minutes
- Assure all a/c switches are OFF on the control panel
- 120V SELECTOR SWITCH to GEN position
- Turn on 120V load while monitoring amp draw
To stop the generator: - Turn off all 120V switches
- 120V SELECTOR SWITCH to OFF
- Press STOP switch until generator is completely stopped
Recommended MaintenanceTASK -- Frequency Oil level -- daily Coolant level -- daily Belt tensions -- daily GVI -- daily Run for 30 minutes -- Weekly Clean sea strainer -- Bi Weekly Oil change -- 150 Hrs Oil filter -- 150 Hrs Racor fuel filter -- 150 Hrs Secondary fuel filter -- 300 Hrs Coolant change -- yearly
|
|